Home Products Surface Water Quality Measurement and Logging Details Eureka Manta

Eureka Manta

product-family

The Eureka Manta is a rugged, easy-to-use multiparameter monitoring sonde with highly customisable configurations.  The sonde comes in 7 different sizes which can accommodate up to 13 sensors.  With 24 available measurement parameters (see below), a Manta configuration can be specified for practically any purpose.  An optional handheld field display unit is available for spot checking or profiling, and the unit can be powered externally, or by using an optional battery pack for long term field deployment in remote locations.  The Manta can also be connected via RS-232 or SDI-12 to Eureka's Eagle-Eye Telemetry system, or any other third-party system to provide real-time water-to-web monitoring. 

 

Parameters:

Temperature

pH

ORP

Conductivity

Dissolved Oxygen (Polarographic or Optical sensors available)

Turbidity

Salinity

Ammonium

Nitrate

Chloride

Depth

Level,

Total Dissolved Solids

Total Dissolved Gases

Chlorophyll,

Rhodamine,

Blue-Green Algae and

Crude Oil.

 top

Unit Sizes and Sensor Configurations Possible:

Sub2-ODO

Comes standard with 6 sensors in less than a 2" diameter housing. Includes Optical Dissolved Oxygen, Temperature, pH, Specific Conductance, ORP and Depth.


Manta2 - 2.0

Supports up to 3 sensors. Most popular configuration is the CTD (Conductivity, Temp, and Depth).


Manta2 - 2.5

Supports up to 5 sensors depending on sensor selection.



Manta2 - 3.0

Supports up to 7 sensors depending on sensor selection.



Manta2 - 3.5

Supports up to 10 sensors depending on sensor selection.



Manta2 - 4.0

Supports up to 14 sensor depending on sensor selection. 

 top

Selected Sensor Data:

Dissolved Oxygen Optical

Eureka Environmental's Manta2 Luminescence Optical dissolved Oxygen Sensor has no replaceable membranes or caps.
Optical DO Sensor
Features:

  • No replaceable membranes or caps
  • Exceptional Accuracy 
  • Luminescent Dissolved Oxygen technology
  • No circulator required
  • The EPA has recommended interim approval of ASTM International Standard Test Method D 888-05 for optical dissolved oxygen. See Memorandum
  • Meets requirements of ASTM method
  • Insensitive  to hydrogen sulfide (H2S) compared to polargraphic DO sensors
  • No damage from sunlight
  • Click here to see deployment from a six week deployment in the Gulf of Mexico

        Specifications:

 Dissolved Oxygen

 

 Range

0 to 25 mg/L

 Accuracy

0.1 mg/L   < 8 mg/L
0.2 mg/L   8-25 mg/L

 Resolution

0.01 mg/L

Size

Medium or Large

 top

 

Dissolved Oxygen (Polarographic)

Eureka Environmental's Manta2 - Dissolved Oxygen Sensor (Polarographic) has been the standard in the industry for 30 years and is EPA approved.
Clark DO Sensor
Features:

  • Complies with Standard Methods Article 4500-AG and EPA Article 360.1
  • Steady-State (Polargraphic) sensor has been trusted for over 30 years
  • Circulator provides fast response time and fresh sample in low flow or stagnant waters
  • Some manufacturers claim "flow independent" but state in fine print "low flow" an exception
  • No "Reconditioning" of Sensor necessary


Specifications:

 Dissolved Oxygen (Polarographic)

 

 Range

0 to 50 mg/L

 Accuracy

+/- 0.2 mg/L for 0 - 20 mg/L
+/- 0.5 mg/L for  > 20 mg/L

 Resolution

 0.01 mg/L

Size

Small

 top

 

Turbidity

Eureka Environmental's Manta2 - 316 SS Turbidity sensor has a self-cleaning wiper that is user programable up to 5 wipes to remove biological growth or debris.
Turbidity Sensor
Features:

  • Accurate up to 3000 NTU's
  • ISO 7027 Compliant
  • Integrated Wiper (Default 1 Wipe)


Specifications:

 Turbidity

 

 Range

0 to 3000 NTU's

 Accuracy

< 1% of reading to 100 NTU
< 3% of reading to 400 NTU
< 5% of reading over 400 NTU

 Resolution

 0.1 NTU

Size

Medium

 top

 

Chlorophyll

Eureka Environmental's Manta2 Chlorophyll a sensor accurately measures in 3 ranges from 0.03 to 500 ug/L.

  • Chlorophyll Sensor
  • Adjustable Secondary Standard available for calibration and quick check
  • Ambient light rejection circuitry and fast response time
  • Turbidity rejection and compact design


Specifications:

 Chlorophyll a

 

 Low  Range
 Med  Range
 High Range

0.03-5µg/L
0.03-50µg/L
0.03-500µg/L

 Accuracy

+/- 3% for signal level equivalents of 1 ppb rhodamine WT dye or higher

 Resolution

 0.01 µg/L

Size

Medium

 top

 

Blue-Green Algae

The Eureka Environmental Blue-Green Algae sensor accurately measures in 3 ranges from 0 - 2,000,000 cells/mL Cyanobacteria (phycocyanin or phycoerythrin). 
Features:

  • Provides accurate measurement of phycocyanin or phycoerythrin using electronic filtration of ambient light and high quality optical components
  • Identifies potential algae blooms and provides substantial cost savings by eliminating cell counting.

Specifications:

 Blue-Green Algae

 

 Range

100-20,000 cells/mL PC or PE
100-200,000 cells/mL PC or PE
100-2,000,000 cells/mL PC or PE

 Accuracy

 +/- 3% signal level equivalents

 Resolution

20 cells/mL

Size

Medium

 top

 

Rhodamine

Eureka Environmental's Manta2 Rhodamine sensor accurately measures in 3 ranges from 
0.04 to 1000 ppb
Features:

  • Available with secondary standard (solid calibration cube) for quick and accurate calibration
  • Solid Calibration Cube can be adjusted to correlate to known dye concentration
  • Ambient light rejection and optical coupling make for accurate readings and fast response time
  • Small sample size volume design and high quality optics provide turbidity rejection

 

Specifications:

 Rhodamine

 

 Range

 0.04 - 10     ppb
 0.04 - 100   ppb 
 0.04 - 1000 ppb  

 Accuracy

 +/- 3% of range

 Resolution

 0.01 ppb

Size

Medium

 top

 

Depth

Eureka Environmental's Manta2 - Depth Sensor is characterized to be extremely accurate with durable SS pressure transducer
Depth Sensor
Features:

  • Available in 5 ranges from 0 - 200 meters
  • Available in absolute or vented (stage)
  • Automatic temperature and salinity compensation
  • Measures accurate barometric pressure for ease of Dissolved Oxygen calibration

 

 Depth

 

 Range

0 to 10 Meters
0 to 25 Meters
0 to 50 Meters
0 to 100 Meters
0 to 200 Meters

Stage 0 to 10 Meters Vented

 Accuracy

0-10 Meters        0.1% of full scale
0-25 Meters        0.1% of full scale
0-50 Meters        0.1% of full scale
0-100 Meters      0.1% of full scale 
0-200 Meters      0.1% of full scale

0-10 Meters Vented Level    .003 Meters

 Resolution

Depth        0.01 Meters
Level         0.001 Meters

Size

Small

 top

 

Temp

The Eureka Environmental Manta2 temperature sensor is a accurate 30k ohm thermistor. Each Manta2 multiprobe includes a temperature sensor.
Temperature Sensor
Features:

  • 316 Stainless Steel housing, 30k ohm thermistor
  • In addition to highly accurate temperature measurements, the temperature sensor is used to provide compensation for Specific Conductance, Dissolved Oxygen, pH, and Ion Selective Electrodes.
  • Manta2 Temperature Sensor is compliant with EPA170.1 and SM2550B


Specifications:

 Temperature

 

 Range

-5 to 50 degrees C 

 Accuracy

 +/- 0.1 degrees C

 Resolution

 0.01 degrees C

Size

Standard with all models

 top

 

pH

Eureka Environmental's Manta2 - pH Sensor w/ rebuildable reference is easy to maintain and typically last more than 5 years.
pH Sensor
Features:

  • Glass bulb with KCL fill permeable to Hydrogen Ions
  • Separate rebuildable reference w/ Teflon junction - No Sensor to replace
  • Easy to maintain sensor
  • Reference is good for low ionic strength waters


Specifications:

 pH

 

 Range

0 - 14 pH Units

 Accuracy

+/- 0.2 pH Units

 Resolution

0.01 Units

Size

Small

 top

 

Conductivity

Eureka Environmental's Manta2 - 4-Electrode Graphite Conductivity Sensor with open flow architecture requires virtually no maintenance. Very accurate sensor for Conductivity, Specific Conductance, Salinity and TDS
Conductivity Sensor
Features:

  • Accurate up to 100,000 uS/cm
  • Open flow graphite prevents sediment fouling
  • Automatic Temperature compensation


Specifications:

 Conductivity

 

 Range

0 - 100 mS 

 Accuracy

 ± (0.5% of reading +/- 0.001 mS/cm)

 Resolution

 0.001

Size

Small

 top

 

Ammonia

The Eureka Environmental Manta2 Ammonia Ion Selective Electrode with replaceable plasticized tips and has a maximum depth of 25 meters.
Features:

  • Easy replaceable tips
  • Submersion Depth and Reliablity highest in the industry
  • Automatic Caculation of Ammonia and Total Ammonia Concentrations
  • Designed for Agricultural Industry and Fertilizer runoff in fresh water
  • Ammonia ISE's will not work in Sea water and interfering ions will effect reading

    Specifications:

Ammonia

 

 Range

0 to 100 mg/l -N Ammonium

 Accuracy

 +/- 10% of reading or 2 mg/l, whichever is greater

 Resolution

 0.1 mg/L -N

Size

Small

 top

 

Nitrate

The Eureka Environmental Manta2 Nitrate Ion Selective Electrode with replaceable plasticized tips and has a maximum depth of 25 meters.
Features:

  • Easy replaceable tips
  • Submersion Depth and Reliablity highest in the industry  (Good to 25 Meters)
  • Automatic Correction for of Temperature and Automatic Compensation for Ionic Strength Concentrations
  • Designed for Agricultural Industry and Fertilizer runoff in fresh water
  • Ammonia ISE's will not work in Sea water and interfering ions will effect reading

    Specifications:

Nitrate

 

 Range

0 to 100 mg/l -N 

 Accuracy

 +/- 10% of reading or 2 mg/l, whichever is greater

 Resolution

 4 digits

Size

Small

 top

 

Chloride

The Eureka Environmental Manta2 Chloride Ion Selective Electrode with replaceable plasticized tips and has a maximum depth of 25 meters.
Features:

  • Easy replaceable tips
  • Submersion Depth and Reliability highest in the industry
  • Automatic Correction of Temperature
  • Good for the measurement of salt intrusion or as an effective tracer for pollution

Specifications:

Chloride

 

 Range

0.5 to 18000 mg/L      

 Accuracy

 +/- 10% of reading or 2 mg/l, whichever is greater

 Resolution

4 digits

Size

Small

 

 

Datasheet pdf70pc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright HydroTerra 2011


Privacy Policy
Disclaimer
Terms & Conditions

ABOUT HYDROTERRA